How to choose separate ultrasonic level meter
¡ômeasuring range
Select model number according to actual range.
Select model number with bigger range if medium level fluctuates strongly.
The range of solid level is generally one-half to two ¨Cthird of that of liquid.
¡ôpower supply
l DC24V POWER SUPPLY£º
1. For two-wire system,the power supply current should not be less than 30 mA.¡¡
2. For three-wire system, the power supply current should not be less than 60 mA.
3. For four-wire system, the power supply current should not be less than 80 mA.
l 220VAC POWER SUPPLY£º
Only for four-wire system, the power supply current should not be less than 50 mA.
¡ôMounting conditions for tank
l closed tank
1. For range less than 8m, the size of orifice on tank should be more than that of DN65 flange;
2. For range of 10m and 12m, the size of orifice on tank should be more than that of DN80 flange;
3. For range of 15m, the size of orifice on tank should be more than that of DN150 flange;
4. For range of 20m, 30mand 40m, the size of orifice on tank should be more than that of DN200 flange;
l open tank
1. For range less than 8m, the diameter of orifice on tank should be more than 65mm.
2. For range of 10m and 12m, the diameter of orifice on tank should be more than 80 and its thickness should be less than 15cm.;
3. For range of 15m, the diameter of orifice on tank should be more than that 150mm and its thickness should be less than 15cm.
4. For range of 20m, 30mand 40m, the diameter of orifice on tank should be more than 200mm and its thickness should be less than 20cm.
l open pond
Fixing stand should be needed.
Open type pond son
Should adopt to add high gearing, keep sensor of the ultrasonic levelmeter forming frost or freezing.
l tank
When mounting flange is applied, means for keeping warm should be done.
If no means to warm, please order the meter with lengthened probe into inner of the tank.
|