DMTFF
FLANGED TRANSIT-TIME ULTRASONIC FLOWMETER
Four lines 16 alphabetical LCD display
Suitable for liquids of high temperature of -40~150 deg C
Multiple outputs including Hart and ModBus outputs
High accuracy by calibrated with flanged pipe in lab
 
DMTF transit time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method in which case the ultra sound transverses the pipe twice, or W-method in which case the ultra sound transverses the pipe four times, or in Z-method in which case the transducers are mounted on opposite sides of the pipe and the ultra sound transverses the pipe only once. The selection of mounting method depends on pipe and liquid characteristics. When the flow meter works, the two transducers transmits and receives ultrasonic signal amplified by multibeam that travels firstly downstream and then upstream (Figure 1). Because  ultra sound travels faster downstream than upstream, there will be a difference of time of flight(¡÷£ô). When the flow is still, the time difference(¡÷£ô) is zero. Therefore, as long as we know the time of flight both downstream and upstream, we can work out the time difference, and then the flow velocity (V) and flow volume (Q) via the following formula.
    
 
 
V= K*D* dt            
  Where:  V: Liquid velocity
  K: Constant
  D: Distance between the two transducers
  dt: difference in time of flight
 
 
Features:
1. Calibrated in manufacture's lab, field setup is unnecessary.
2. Measurement is independent of fluid nature with wider applications than magnetic meters.
3. Available including up to 8GB event data logger, can search the¡¡event of totalizer flow, flow rate, velocity etc.¡¡
4. Parallel operation of positive, negative and net flow totalizer, while the output of totalizer pulse and frequency output are transmitted via open collector.
5. Re-calibration or maintenance is easy, no processing interruption (just plug out the inserted transducers from pipe line, when re-calibration or maintenance is finished), can be hot-tapped.
 
 
Transmitter
Power Supply
(Std) 10-28 VDC @ 2.5VA max.115/230VAC 50/60Hz ¡À15%@ 5VA max. Solar energy
Velocity
0 ~ ¡À40 ft/s (0 ~ ¡À12m/s), bi-directional
Display
4 line¡Á16 English letters LCD back lit, can display total flow, flow rate, velocity and meter running status etc. 
Units
Rate
Totalized
User Configured (English and Metric);
Rate and Velocity Display;
(FWD, NET, REV or BATCH) gallons, ft³, barrels, lbs, litters, m³,kg
Output
4~20mA, Pulse, Relay, RS232C or RS485, options: up to 8 GB Data logger, Hart +(4~20mA), Modbus
Accuracy
¡À1.0% of reading at rates >0.5 m/s);
¡À0.005 m/s of reading at rates<0.5 m/s
Sensitivity
Flow Rate: 0.001f/s (0.0003m/s)
Repeatability
0.2% of reading
Security
Keypad lockout, access code enable
Dimensions
Std.:242*190*115 Weight: <2.5kg
Exp: 255*220*110 Weight: <5.0kg
Transducer
Liquid Types Supported
Virtually most any liquid containing less than 2% total suspended solids (TSS) or aeration
Suited Liquid Temperature
Std. Temp. Transducer: -40¡æ~121¡æ
High Temp. Transducer : -40¡æ~150¡æ
Cable Length
Std: 20 feet (6m); Opt: Maximum: 990 feet (300m)
Pipe Size
ND65~ND3000; select S type flange transducers if pipe
DMTFF Flanged Ultrasonic Flow Meter Selection Table
 
   Model        DMTFF   ¨C X   ¨C X  X  X   X *£¨Transducers£©                                        
Flanged Series
 
Approvals
 
N¡ªN/A
 
Ex¡ªExdIIBT6
 
Power Supply
 
A¡ª110VAC
 
B¡ª220VAC
 
E¡ª24VDC   
 
Output Selection 1
 
N¡ªN/A
 
1¡ª4-20mA
 
2¡ªPulse Output£¨Flow Rate or Totalizer Output£©  
 
3¡ªRelay
 
4¡ªRS232
 
5¡ªRS485
 
6¡ªHart+(4-20mA)
 
7¡ªModBus 
 
8¡ªData Logger & Software
9¡ªHeat Flow
 (Two loops temperature transmitter 4-20mA input)
 
Output Selection 2
 
Same as Output Selection 1
 
Output Selection 3
 
Same as Output Selection 1
 
 
 
 
 
Transducer Selection Table of DMTFF Insertion Ultrasonic Flow Meter
 
                           DC   -    X  -   X   -  X  -  X  - X 
 
 
 
 
 
 
 
Flanged Series
 
Transducer Type
 
0¡ªCommon flanged type (65-2000mm)
 
1¡ªS-Series small flanged type (20-65mm)   
 
2¡ª Very low flow rate flanged type (15-50mm)
 
Pressure Level
 
A¡ª1.0MPa
 
 
B¡ª1.6 MPa
 
C¡ªPlease contact the factory if High Pressure
 
Pipeline Material
 
 
 
0¡ªCarbon Steel
 
 
 
1¡ªStainless Steel
Pipeline Diameter
0012¡ªDN12
 
1200¡ªDN1200
 
Cable Length
 
XXX (meter)
The Maximum can reach to 300m, also can contact with the factory for details.
 
Parts Number Construction example:
For example: DMTFF¨CN-B1NN-N/DF-0-B-0-0400-030
Note: DMTF Flanged ultrasonic flow meter, 220VAC power supply, 4-20mA output, non-multiple output selection; common pipeline Flange mounting transducer, pressure is 1.0Pa, pipeline is ND400, transducer cable length is 30m.