DMTFD
CENTRE-INSERTION TRANSIT-TIME ULTRASONIC FLOW METER |
Four line 16 alphabetical backlit LCD display Easy installation on the same side of pipe Low mounting space requirements Suitable for large pipe partially buried or emerged Higher accuracy than other point insertion flowmeters
The Centre-Insertion Series is an improved mode for Standard Insertion Series. The Centre-Insertion transducer is easy to mount; two transducers are installed at the same side. One transducer is the same with standard insertion transducer, but the other transducer is always inserted into the centre point of pipe line, the insertion length varies with the pipe line diameter. In fact, the ultrasonic flight distance is half of the standard insertion mode. The difference in time of flight also is half of the standard insertion mode. |
Principle of Operation
DMTF transit time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method in which case the ultra sound transverses the pipe twice, or W-method in which case the ultra sound transverses the pipe four times, or in Z-method in which case the transducers are mounted on opposite sides of the pipe and the ultra sound transverses the pipe only once. The selection of mounting method depends on pipe and liquid characteristics. When the flow meter works, the two transducers transmits and receives ultrasonic signal amplified by multibeam that travels firstly downstream and then upstream (Figure 1). Because ultra sound travels faster downstream than upstream, there will be a difference of time of flight(¡÷£ô). When the flow is still, the time difference(¡÷£ô) is zero. Therefore, as long as we know the time of flight both downstream and upstream, we can work out the time difference, and then the flow velocity (V) and flow volume (Q) via the following formula.

V= K*D* dt Where: V: Liquid velocity K: Constant D: Distance between the two transducers dt: difference in time of flight |
Features:
1.One obvious advantage of Centre-Insertion Series compared with standard Insertion Series is easy to install. The two transducers are mounted in the same side of pipe line, so even the pipe partially buried underground, it still can be installed in the Centre-Insertion mode.
2.Transducers are easy to locate. 3. compared with standard Insertion Series£¬Centre-Insertion Series is less installation spacing requirement. Its longitudinal space is half of standard insertion series, and almost no transverse space demand. 4. Due to the measuring accuracy is based on radius line average velocity; the Centre-Insertion Series is more accurate than all the types of point insertion flow meters.
5. Standard Series and Explosion-Proof types are available. |
|
Transmitter |
Power Supply |
(Std) 10-28 VDC @ 2.5VA max.115/230VAC 50/60Hz ¡À15%@ 5VA max. Solar energy |
|
Velocity |
0 ~ ¡À40 ft/s (0 ~ ¡À12m/s), bi-directional |
|
Display |
4 line¡Á16 English letters LCD back lit, can display total flow, flow rate, velocity and meter running status etc. |
|
Units
Rate
Totalized |
User Configured (English and Metric);
Rate and Velocity Display;
(FWD, NET, REV or BATCH) gallons, ft³, barrels, lbs, litters, m³,kg |
|
Output |
4~20mA, Pulse, Relay, RS232C or RS485, options: up to 8 GB Data logger, Hart +(4~20mA), Modbus |
|
Accuracy |
¡À2.0% of reading at rates >0.5 m/s |
|
¡À0.003 m/s of reading at rates<0.5 m/s |
|
Sensitivity |
Flow: 0.001f/s (0.0003m/s) |
|
Repeatability |
0.2% of reading |
|
Security |
Keypad lockout, access code enable |
|
Transmitter Size |
Std.:242*190*115 Weight: <2.5kg |
|
Exp: 255*220*110 Weight: <5.0kg |
|
Transducer |
Liquid Types Supported |
Virtually most any liquid containing less than 2% total suspended solids (TSS) or aeration |
|
Pipe Range |
65mm-4570mm |
|
Suited Liquid Temperature |
Std. Temp. Transducer: -40¡æ~121¡æ
High Temp. Transducer: -40¡æ~150¡æ |
|
Cable Length |
Shielded transducer cable. Standard length 20fts (6m). Can be extended to 990fts (300m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power line; neither should it be close to strong interference source such as power transformers. |
|
DMTFD Centre-Insertion Ultrasonic Flow Meter Selection Table
|
Model |
DMTFD ¨C X ¨C X X X X ¨C X / * (Transducers) |
|
|
|
|
|
|
/ |
* |
(Transducers£© |
|
Approvals |
|
|
N¡ªN/A |
|
|
Ex¡ªExdIIBT6 |
|
|
Power Supply |
|
|
A¡ª110VAC |
|
|
B¡ª220VAC |
|
|
E¡ª24VDC |
|
|
Output Selection 1 |
|
|
N¡ªN/A |
|
|
1¡ª4-20mA |
|
|
2¡ªPulse Output£¨Flow Rate or Totalizer Output£© |
|
|
3¡ªRelay |
|
|
4¡ªRS232 |
|
|
5¡ªRS485 |
|
|
6¡ªHart + (4-20mA) |
|
|
7¡ªModBus |
|
|
8¡ªData Logger
9¡ªHeat Flow (Two loops temperature
Transmitter 4-20mA input) |
|
|
Output Selection 2 |
|
|
Same as Output Selection 1 |
|
|
Output Selection 3 |
|
|
Same as Output Selection 1 |
|
|
Product Service Code |
|
|
Please contact the factory for the details, if not available, select: N |
|
|
Transducer Selection Table of DMTFF Insertion Ultrasonic Flow Meter
|
|
|
|
|
|
|
|
Model |
DD ¨C x x ¨C x ¨C x ¨Cx |
¨CX |
X |
¨CX |
¨CX |
¨CX |
|
|
Transducer Type |
|
|
1¡ªFor Welded Pipe |
|
|
2¡ªFor Cast Iron Pipe |
|
|
3¡ªFor Cement Pipe |
|
|
Transducers Temperature |
|
|
N¡ª -40¡«121¡æ |
|
|
H¡ª -40¡«150¡æ |
|
|
Pipeline Diameter |
|
|
A¡ª0-500mm |
|
|
B¡ª500-800mm |
|
|
C¡ª900-1200mm |
|
|
D¡ª1300-1600mm |
|
|
E¡ª1700-2200mm |
|
|
F¡ª2300-2800mm |
|
|
G¡ª2900-4500mm |
|
|
Cable Length |
|
|
XXX (meter) |
|
|
Work Underwater |
|
|
0¡ªNO |
|
|
1¡ªYES
Parts Number Construction example:
For example£ºDMTFD-N-B1NN-N/DD-l-N-B-030-0
Note: DMTFD Centre-insertion ultrasonic flow meter, 220VAC power supply, 4-20mA output,
Non-multiple output selections; welded directly for the pipe of transducers, standard
transducer temperature, installing pipeline DN500-DN800mm, transducer cable length is 30m,
no underwater working conditions. |
| |
|
|
|