DMTFD
CENTRE-INSERTION TRANSIT-TIME ULTRASONIC FLOW METER


Four line 16 alphabetical backlit LCD display
Easy installation on the same side of pipe
Low mounting space requirements
Suitable for large pipe partially buried or emerged
Higher accuracy than other point insertion flowmeters

The Centre-Insertion Series is an improved mode for Standard Insertion Series. The Centre-Insertion transducer is easy to mount; two transducers are installed at the same side. One transducer is the same with standard insertion transducer, but the other transducer is always inserted into the centre point of pipe line, the insertion length varies with the pipe line diameter. In fact, the ultrasonic flight distance is half of the standard insertion mode. The difference in time of flight also is half of the standard insertion mode.

Principle of Operation
 
DMTF transit time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method in which case the ultra sound transverses the pipe twice, or W-method in which case the ultra sound transverses the pipe four times, or in Z-method in which case the transducers are mounted on opposite sides of the pipe and the ultra sound transverses the pipe only once. The selection of mounting method depends on pipe and liquid characteristics. When the flow meter works, the two transducers transmits and receives ultrasonic signal amplified by multibeam that travels firstly downstream and then upstream (Figure 1). Because  ultra sound travels faster downstream than upstream, there will be a difference of time of flight(¡÷£ô). When the flow is still, the time difference(¡÷£ô) is zero. Therefore, as long as we know the time of flight both downstream and upstream, we can work out the time difference, and then the flow velocity (V) and flow volume (Q) via the following formula.
    
 
 
V= K*D* dt            
  Where:  V: Liquid velocity
  K: Constant
  D: Distance between the two transducers
  dt: difference in time of flight
Features:
1.One obvious advantage of Centre-Insertion Series compared with standard Insertion Series is easy to install. The two transducers are mounted in the same side of pipe line, so even the pipe partially buried underground, it still can be installed in the Centre-Insertion mode.
2.Transducers are easy to locate.
3. compared with standard Insertion Series£¬Centre-Insertion Series is less installation spacing requirement. Its longitudinal space is half of standard insertion series, and almost no transverse space demand.
4. Due to the measuring accuracy is based on radius line average velocity; the Centre-Insertion Series is more accurate than all the types of point insertion flow meters.
5. Standard Series and Explosion-Proof types are available.
Transmitter
Power Supply
(Std) 10-28 VDC @ 2.5VA max.115/230VAC 50/60Hz ¡À15%@ 5VA max. Solar energy
Velocity
0 ~ ¡À40 ft/s (0 ~ ¡À12m/s), bi-directional
Display
4 line¡Á16 English letters LCD back lit, can display total flow, flow rate, velocity and meter running status etc. 
Units
Rate
Totalized
User Configured (English and Metric);
Rate and Velocity Display;
(FWD, NET, REV or BATCH) gallons, ft³, barrels, lbs, litters, m³,kg
Output
4~20mA, Pulse, Relay, RS232C or RS485, options: up to 8 GB Data logger, Hart +(4~20mA), Modbus
Accuracy
¡À2.0% of reading at rates >0.5 m/s
¡À0.003 m/s of reading at rates<0.5 m/s
Sensitivity
Flow: 0.001f/s (0.0003m/s)
Repeatability
0.2% of reading
Security
Keypad lockout, access code enable
Transmitter     Size
Std.:242*190*115 Weight: <2.5kg
Exp: 255*220*110 Weight: <5.0kg
Transducer
Liquid Types Supported
Virtually most any liquid containing less than 2% total suspended solids (TSS) or aeration
Pipe Range
65mm-4570mm
Suited Liquid Temperature
Std. Temp. Transducer: -40¡æ~121¡æ
High Temp. Transducer: -40¡æ~150¡æ
Cable Length
Shielded transducer cable. Standard length 20fts (6m). Can be extended to 990fts (300m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power line; neither should it be close to strong interference source such as power transformers.
DMTFD Centre-Insertion Ultrasonic Flow Meter Selection Table
 
Model
DMTFD ¨C  X ¨C X   X      X    X  ¨C X / * (Transducers)
 
 
 
 
 
 
/
*
(Transducers£©
Approvals
 
N¡ªN/A
 
Ex¡ªExdIIBT6
 
Power Supply
 
A¡ª110VAC
 
B¡ª220VAC
 
E¡ª24VDC    
 
Output Selection 1
 
N¡ªN/A
 
1¡ª4-20mA
 
2¡ªPulse Output£¨Flow Rate or Totalizer Output£©  
 
3¡ªRelay
 
4¡ªRS232
 
5¡ªRS485
 
6¡ªHart + (4-20mA)
 
7¡ªModBus   
 
8¡ªData Logger
9¡ªHeat Flow  (Two loops temperature
 Transmitter 4-20mA input)  
 
Output Selection 2
 
Same as Output Selection 1
 
Output Selection 3 
 
Same as Output Selection 1
 
Product Service Code
 
Please contact the factory for the details, if not available, select: N
 
 
 
Transducer Selection Table of DMTFF Insertion Ultrasonic Flow Meter
 
 
 
 
 
 
 
 
  Model
DD       ¨C x    x   ¨C  x  ¨C  x   ¨Cx
¨CX
X
¨CX
¨CX
¨CX
 
Transducer Type
 
1¡ªFor Welded Pipe                                   
 
2¡ªFor Cast Iron Pipe       
 
3¡ªFor Cement Pipe
 
Transducers Temperature
 
N¡ª -40¡«121¡æ
 
H¡ª -40¡«150¡æ
 
Pipeline Diameter
 
A¡ª0-500mm
 
B¡ª500-800mm
 
C¡ª900-1200mm
 
D¡ª1300-1600mm
 
E¡ª1700-2200mm
 
F¡ª2300-2800mm
 
G¡ª2900-4500mm
 
Cable Length
 
XXX (meter)
 
Work Underwater  
 
0¡ªNO
 
1¡ªYES
 
Parts Number Construction example:
For example£ºDMTFD-N-B1NN-N/DD-l-N-B-030-0
Note: DMTFD Centre-insertion ultrasonic flow meter, 220VAC power supply, 4-20mA output,
Non-multiple output selections; welded directly for the pipe of transducers, standard
transducer temperature, installing pipeline DN500-DN800mm, transducer cable length is 30m,
no underwater working conditions.